When designing the membrane surface modeling, a large slope of the membrane surface should be adopted, and the drainage path of the membrane surface should be convenient, and the corresponding vertical load should be applied on the membrane surface according to the rainfall at the location of the project, and the contour map of the membrane surface after deformation should be checked;
If there is an area that is similar to a circle or an oval shape other than the high point, the shape of the membrane surface should be modified; When tensioning, the pretension of the membrane surface needs to reach the design pretension level; The relaxed membrane surface should be re-stretched in time; In the case of membrane water, it is necessary to manually assist in drainage in time, and take corresponding remedial and modification measures.